AC6000
TM
Configuration Manual 22
UNION COMMUNITY Co., Ltd. 44-3 Hyundai Topics Building, Bangi-dong,
Songpa-gu, Seoul, Korea 138-050, Tel: 82-2-6488-3000, Fax: 82-2-6488-3099,
Be aware of certain fingerprint conditions
Depending on the user’s fingerprint condition, some fingerprints may not be
used or may cause an inconvenience.
If the fingerprint is damaged or very unclear, then it cannot be recognized.
Please use a password instead in this case.
When a finger is dry, breathe on the finger for smooth operation.
For kids, it may be tricky or impossible to use the terminal because their
fingerprints are too small or very unclear. It is recommended to register
their fingerprints every six months.
For the elderly, it may not be possible to register their fingerprints if there
are too many fine lines on the fingerprints.
If fingerprints are very unclear, it may be convenient if you register 2~3
fingerprints.
It is recommended that you register more than 2 fingerprints.
1.10. Ultraviolet (UV) Option
The UV function is for sterilizing the window surface of the fingerprint sensor. This is available as an
option only. The UV will turn on if the approach sensor is inactive and the fingerprint window cover is
closed. You should see the UV icon turning blue and white when it is active, and the blue LED inside
the fingerprint sensor window will be on. When the approach sensor is activated (person is near the
terminal) or the fingerprint sensor door is opened the UV will turn off. Also in order to conserve the life
of the UV LED the LED will turn off automatically after 20 minutes.
1.11. User Environment [illumination specification]
This is the recommended illumination area the terminal should be located in to provide sufficient
lighting for the camera.
Illumination (recommend): 75LUX~more than150LUX (illumination classification: greater than E)
The minimum movement of illumination: 8LUX~10 LUX (illumination classification: B)
KS Standard illumination value with a variety of conditions
Conditions
Illumination
classification
Illumination range Type of Lighting
Full Dark Environments
(ex. In the theater)
A 3-4-6
Semi Dark Environment (ex.
Corridors)
B 6-10-15
Public place in dark
(ex. Museum, Elevator)
C 15-20-30
Space lighting,
natural light
(outdoor),
Fluorescent lamp