3.2.7.2. Wiegand Settings
Wiegand support is available in the terminal for connecting external wiegand card readers or
controllers. Note that in UNIS a fully customizable setting for Wiegand Input and Wiegand Output
can be programmed. The parity, number of bits, data fields can be set and downloaded to the
terminal. It is recommended to setup the wiegand programming from UNIS.
Wiegand Connection Option 1
When using an external reader that supports wiegand you can connect the reader to Wiegand IN0
and Wiegand IN1. This will allow the reader data to be sent to the AC6000 terminal.
IN0 = Data0
IN1 = Data1
Wiegand Connection Option 2
When using an external controller that supports wiegand, you can use the AC6000 as a dummy
reader. The AC6000 will send the site code and user id to the external controller.
OUT0 = Data0
OUT1 = Data1